Cybersecurity Under Pressure examines real incidents, technical research and security decisions across industrial systems, railways and connected vehicles. Antonio González connects attack mechanisms with engineering constraints, operational resilience and product-security evidence. Explore OT and ICS security, automotive and railway cybersecurity, software supply chains and the decisions behind secure operations.

Play
  • 155 episodes
  • a few times a week
  • Avg 35 min
  • English
Counted on this page — what you have heard stays on this device, so it is not something the list can be paged by.
  • Yesterday · 35 min

    OT Recovery: The PLC Backup Restored. Is the Process Ready to Restart?

    A replacement PLC can load the approved project and still be wrong for the process it controls. The backup may omit a calibration offset the plant now depends on. Restoring the latest runtime snapshot creates the opposite risk: bringing back an unapproved override or a manipulated setpoint. This technical decision analysis examines what to restore from the approved engineering baseline, which retained values to recover selectively, and what evidence operations needs before re-energizing outputs. The key question: can your team prove that the restored controller is ready for the process as it exists today? From Cybersecurity Under Pressure The Restart Bottleneck Is Not the Backup. It Is the Evidence. OT Vendor Ransomware: Managing Lock-In and Recovery Risk Minnesota Water Cyberattacks: When OT Security Meets Physical Risk When a Critical PLC Vulnerability Meets Brownfield Reality Oldsmar Revisited: Remote Access and the Limits of the Evidence From other podcasts Rapid Recovery After an Attack A Case Study on Developing a Unique OT Disaster Recovery Plan Rethinking Ransomware and Human Error in Industrial Security Responding to Ransomware Attack: Case Study Why Should You Talk About Incident Response? Part 4

  • Friday · 46 min

    The Patch Is Deferred. Is the Compensating Firewall Rule Still There?

    An OT patch is deferred because production cannot stop. The risk register says a firewall rule compensates for the exposure. But after maintenance, troubleshooting or a loss of connectivity with the SOC, what evidence shows that the rule still blocks the intended path? This technical decision analysis uses a hypothetical plant scenario to compare configuration change alerts, baseline checks and tests of actual traffic reachability. It also examines what evidence the plant can preserve locally when central logging is unavailable, who owns escalation, and what should trigger a review of the patch deferral.

  • Wednesday · 41 min

    The UDS Routine Works. Does It Refuse the Wrong Vehicle State?

    A valid diagnostic session can still issue a request the vehicle should refuse. This episode opens with a hypothetical remote-attack scenario, not a report of a documented incident. It asks when an ECU should reject a UDS RoutineControl (0x31) request because the vehicle state is unsafe, stale or cannot be verified. We compare state checks at the gateway and at the target ECU, distinguish a diagnostic response from what the routine actually does, and discuss how hardware-in-the-loop fault injection can test those assumptions. The hardest question comes after the routine starts: what should happen if a required condition disappears during execution?

  • November 16 · 33 min

    Shared Railway Maintenance Credentials: What Does the Safety Case Allow?

    A shared maintenance password on a legacy train is a security risk. Replacing it can also affect diagnostic compatibility, supplier support and the evidence behind the Safety Case. What can the operator change now, and what needs a planned engineering change? This technical decision analysis weighs individual access at the gateway, controls on maintenance sessions and a phased move away from shared credentials. It examines what those measures leave exposed at a local diagnostic port, what evidence the operator and supplier need before making changes, and how to compare the cost of keeping compensating controls with the cost of replacing the credential. The scenario illustrates an engineering decision; it is not a report of a documented incident.

  • November 13 · 31 min

    Validating Automotive Supplier VEX Claims

    A supplier declares an automotive ECU not affected by a vulnerability identified in a software component. What evidence should the manufacturer request before relying on that assessment? This Friday episode explores a hypothetical supplier-assurance scenario involving closed-source firmware, a safety-related ECU and production constraints. The discussion contrasts component absence with code reachability, examines build-specific evidence and considers the trade-offs between accepting an assessment, requesting further investigation, applying containment and updating software. Editorial clarification: this is not a documented vehicle incident. A VEX statement does not by itself determine a TARA risk rating or authorize risk retention. Binary analysis findings remain bounded by their method and coverage. The evidence package discussed is an assurance proposal, not a universal VEX requirement; regulatory and safety consequences require case-specific assessment. More analysis: https://cybersecurityunderpressure.com

  • November 11 · 32 min

    PLC Logic Changes During Live Production: An OT Pressure Test

    What if a PLC program change is flagged while a factory remains in production and process indicators appear normal? This Wednesday episode uses a hypothetical engineering scenario to examine the gap between apparent process stability and confidence in controller logic. We compare possible change paths, engineering access, network visibility, controller state and the safety consequences of an unverified response. An online edit, a compromised engineering workstation and manipulation of operator views are hypotheses discussed in the dialogue, not established findings from a documented intrusion. The episode also examines the limits of live verification, the need for a trustworthy baseline and plant-safe recovery decisions. This is an analytical scenario, not a report of a confirmed attack. Specific mechanisms and outcomes depend on the PLC model, configuration, tooling and evidence available at a real site.

  • November 9 · 32 min

    Who Can End a Supplier Session When the Line Is Down?

    A production line is stopped, and a supplier needs an engineering connection to diagnose the fault. In this explicitly hypothetical CUP scenario, the same legacy session can also download a PLC program. The question is who can constrain and end its authority when recovery is urgent. We trace the path from supplier identity through remote access, a plant-controlled workstation, the engineering tool and the controller. A broker disconnect, account disable and controller-side termination do not necessarily have the same effect; none can undo a program already downloaded. MFA, recording and a jump host add control points, but do not make a change-capable tool read-only. We discuss named access, expiry, local supervision, alternative routes, surviving sessions and a bounded non-production acceptance exercise. This is an engineering analysis, not a reported incident, product vulnerability or completed experiment. NIST SP 800-82 Rev. 3 provides context; the revocation sequence and acceptance checks are CUP recommendations. Read the companion analysis: https://cybersecurityunderpressure.com/analysis-supplier-session-revocation-legacy-ot

  • November 6 · 42 min

    How Attackers Weaponized Evernote Against SCADA

    What happens when a trusted note-taking workflow becomes a route into an industrial control environment? This episode examines an Evernote-to-SCADA attack path and the boundary between ordinary collaboration tools and operational access. We consider how attackers can use familiar cloud content, links or shared documents to influence users and systems that support industrial operations. The practical questions are where trust is established, what privilege is needed to reach an engineering workstation or SCADA component, and which actions the available evidence actually supports. A suspicious document alone does not prove process manipulation. For OT teams, the response starts with controlled access paths, isolation between corporate and plant networks, application and identity telemetry, and verification of changes at the engineering and control layers. Detection and containment must respect plant safety and availability. The lesson is to test the complete route from external content to privileged industrial action, not merely the first click.

  • November 4 · 42 min

    How Incomplete SBOMs Hide Critical Vulnerabilities

    An SBOM is only as useful as the components and relationships it captures. This episode examines how incomplete software bills of materials can hide critical vulnerabilities when transitive dependencies, embedded packages, firmware or build artifacts are missed. We discuss the difference between generating an SBOM and accepting it as evidence: checking scope against the delivered build, reconciling package and version identifiers, testing dependency depth and validating the tool configuration. A clean vulnerability scan cannot establish absence of risk if the underlying inventory is incomplete. For automotive and industrial systems, OEMs, suppliers and operators must trace findings to the exact delivered baseline, assess exploitability in context and maintain that evidence as products change. An SBOM supports this work; it does not replace product-level security analysis.

  • November 3 · 2 min

    VMS Privilege Escalation: When Edit Rights Become Server Control | CUP Micro Brief

    Application edit rights and operating-system administration are not the same security boundary. This CUP Micro Brief shows how an over-privileged video-management service can turn a limited application role into control of the underlying server. Related CUP episodes: Siemens Siveillance: When Edit Access Enables Code Execution Johnson Controls Airwall: The Risk Behind a Hardcoded Key Industrial Identity Security: The Risk in Software-Defined Factories

  • November 2 · 41 min

    Stopping Fake Emergency Braking in Connected Cars

    Can a connected vehicle reject a forged emergency-braking warning without suppressing a legitimate safety message? This episode examines false emergency electronic brake light warnings in connected-car and V2X environments. We break down the trust boundary between a valid sender credential, a plausible road event and the vehicle response that follows. Cryptographic validity can authenticate a source, but it does not automatically prove that the reported event is true. The discussion covers message authentication, plausibility checks, certificate and credential revocation, duplicate and anomalous-event detection, safe degradation, incident response and the operational limits of automated blocking. It also separates prevention, detection and containment, because each control proves something different. Key lessons: • Bind message acceptance to authenticated and authorized senders • Correlate warnings with vehicle, sensor and situational context • Design revocation and trust updates for real driving conditions • Avoid fail-open and fail-silent responses • Validate the complete path from received warning to vehicle action The episode does not assume that every V2X deployment is vulnerable or that a forged warning necessarily causes braking. Impact depends on the protocol, implementation, vehicle state and the control path exposed by the receiving system. You can also listen to Cybersecurity Under Pressure on PlayPodcast.net.

  • October 31 · 4 min

    OT Maintenance Windows: Monitoring Temporary Access | CUP Focus

    Planned downtime concentrates contractors, temporary access, firmware changes and disabled alerts in the same period. This CUP Focus explains why maintenance windows require tighter monitoring and evidence, not relaxed controls. Format: CUP Focus, a self-contained section from the Cybersecurity Under Pressure archive. Related CUP episodes: Kinetic AI and Critical Infrastructure: Connecting Cyber and Physical Risk OT Remote Access: Closing the Path When the Work Ends OT Session Hijacking: Revoking Trusted Engineering Access Legacy VPNs in OT: Remote Access and the Cost of Disruption

  • October 30 · 38 min

    Oldsmar Revisited: Remote Access and the Limits of the Evidence

    Editorial context: The February 2021 Oldsmar incident was initially reported as an unauthorized remote-access attempt to alter water-treatment dosing. In 2023, the FBI said it could not confirm that a targeted cyber intrusion had initiated the incident. Treat the reported attack sequence discussed in this episode as an account with unresolved evidentiary limits, rather than a proven intrusion. Authorities reported no significant effect on treated water and no danger to the public. Revisit the Oldsmar case through the operational questions it raises for water utilities: who can reach an operator workstation, what authority a remote session carries, how process changes are detected, and what evidence supports a response decision. The practical focus is remote-access governance, independent process safeguards, operator visibility and incident evidence. Lessons derived from the reported scenario do not establish what actually caused the Oldsmar event. Sources and further reading: Original Pinellas County Sheriff report: https://www.pinellassheriff.gov/21-015-detectives-investigate-computer-software-intrusion-at-oldsmar-s-water-treatment-plant FBI investigation records: https://vault.fbi.gov/attempted-hacking-of-oldsmar-water-treatment-plant-on-february-5-2021 WUSF, April 2023 follow-up: https://www.wusf.org/local-state/2023-04-13/official-hack-oldsmar-city-water-treatment-plant-2021 CISA advisory AA21-042A: https://www.cisa.gov/news-events/cybersecurity-advisories/aa21-042a Cybersecurity Under Pressure. Real Attacks, Real Lessons.

  • October 29 · 2 min

    Railway Diagnostic Security: Protecting Privileged Access | CUP Micro Brief

    A railway diagnostic platform may not execute the safety function, but it can expose topology, privileged sessions and a pivot path toward operational assets. This CUP Micro Brief explains why monitoring systems still belong inside the security boundary. Related CUP episodes: Frauscher FDS102: Securing Railway Diagnostic Access Legacy Railway Security: Patching and Validation Constraints Railway OT Segmentation: Protecting the Certified Core Railway Cybersecurity: Service Risk Beyond the SIL Boundary

  • October 29 · 5 min

    Industrial 5G Security: Protecting the Wireless Conduit | CUP Focus

    A wireless conduit cannot be protected like a copper port. This CUP Focus connects 5G device identity, subscriber credentials, edge routing and passive application monitoring without adding latency to deterministic industrial traffic. Format: CUP Focus, a self-contained section from the Cybersecurity Under Pressure archive. Related CUP episodes: Industrial 5G Jamming: Protecting Control When the Radio Fails Industrial 5G Security: Designing for Lost Connectivity When 40 Milliseconds Become an OT Incident | CUP Micro Brief FRMCS Security: Why a Mobile Network SLA Is Not a Safety Case

  • October 28 · 40 min

    How Volt Typhoon Weaponizes Active Directory

    Volt Typhoon turns trusted administration into a path toward critical infrastructure. This episode examines how stolen credentials, Active Directory compromise and living-off-the-land activity can undermine confidence in the systems operators depend on. We explore the identity boundary between enterprise IT and operational technology, the evidence defenders need to distinguish legitimate administration from an intrusion, and the recovery decisions that follow a suspected domain compromise. Sources and further reading: Joint CISA advisory AA24-038A: https://www.cisa.gov/news-events/cybersecurity-advisories/aa24-038a Joint CISA advisory AA23-144A: https://www.cisa.gov/news-events/cybersecurity-advisories/aa23-144a Cybersecurity Under Pressure. Real Attacks, Real Lessons.

  • October 27 · 2 min

    Industrial Router Security: When SMS Authentication Fails Open | CUP Micro Brief

    An industrial router disables SMS password checks after five failed attempts. This CUP Micro Brief examines the availability logic behind the fail-open design and why it becomes dangerous on a cellular attack surface. Related CUP episodes: Weidmüller Router Security: When Segmentation Becomes an Attack Path Industrial Network Security: Designing for Operational Resilience Legacy VPNs in OT: Remote Access and the Cost of Disruption OT Remote Access: Closing the Path When the Work Ends

  • October 27 · 4 min

    SBOM and VEX: Proving Vulnerability Reachability | CUP Focus

    Component presence and practical exposure are different facts. This CUP Focus explains how static and dynamic reachability analysis support VEX decisions, reduce false positives and create defensible evidence when an actively exploited vulnerability appears. Format: CUP Focus, a self-contained section from the Cybersecurity Under Pressure archive. Related CUP episodes: Cyber Resilience Act: Evidence and the 24-Hour Reporting Clock SBOM and VEX: Turning Vulnerability Data into OT Risk Decisions SBOM and VEX: Challenging Supplier Vulnerability Claims NIST IR 8536: Verifying the Software Supply Chain

  • October 26 · 36 min

    A Trusted Engineering Workstation Can Still Deploy a Malicious Flow

    An unauthenticated flow editor can turn an industrial gateway into a code-execution platform. This episode examines the Siemens SIMATIC IoT2050 Advanced case and the operational choices around patching, access restrictions and containment. Siemens advisory SSA-834709 documents CVE-2026-58115 in affected devices running Industrial OS with Node-RED installed before V4.3.4.1. An unauthenticated attacker who can reach the vulnerable HTTP interface may create malicious flows and execute code with maximum privileges. Siemens recommends updating to V4.3.4.1 or later. Editorial clarification The factory and incident-response situations in the discussion are hypothetical. Compromise of this gateway does not by itself prove authority to write to a PLC or manipulate a physical process. That depends on reachable services, protocols, credentials and controller-side controls. Any dependence of HMI visibility or alarms on this gateway must also be established for the actual installation; it is not a product-wide finding in the Siemens advisory. The discussion overstates the difficulty of detection at approximately 16:48. Legitimate-looking HTTP traffic can make malicious intent difficult to distinguish, but detection is not inherently impossible. Flow-change records, access logs, approved-configuration comparisons and host or network monitoring may provide evidence, depending on deployment and coverage. Containment must follow the plant-specific response plan and process-safety assessment. Neither disconnecting every gateway nor keeping every connection alive is a universal rule. Preserve required safe control and trustworthy monitoring while restricting the attacker's access. These qualifications take precedence over broader language in the discussion. Chapters 00:00 Introduction 00:47 The Siemens Node-RED case 07:24 The Technical Breakdown 16:48 The Operational Decisions 25:19 The Pressure Test 32:56 The Key Takeaways 35:34 Closing Cybersecurity Under Pressure. Real Attacks, Real Lessons. https://cybersecurityunderpressure.com/ Primary sources Siemens ProductCERT SSA-834709: https://cert-portal.siemens.com/productcert/html/ssa-834709.html Node-RED security guidance: https://nodered.org/docs/user-guide/runtime/securing-node-red NIST SP 800-82 Rev. 3: https://csrc.nist.gov/pubs/sp/800/82/r3/final

  • October 24 · 3 min

    Connected Vehicle Security: From Cloud API to In-Vehicle Control | CUP Focus

    The API gateway may validate a remote command while the internal vehicle network accepts it without equivalent checks. This CUP Focus explains why cloud authorization, telematics and in-vehicle trust must be assessed as one attack path. Format: CUP Focus, a self-contained section from the Cybersecurity Under Pressure archive. Related CUP episodes: Your License Plate Is the Password: What the Kia API Hack Revealed When a License Plate Becomes a Password | CUP Micro Brief Jeep Hack Lessons: Testing Vehicle Gateway Trust Boundaries Automotive Extortion: Protecting Cloud, APIs and the Update Chain