0:00-1:12:58
Streams straight from the publisher. podnod never proxies or re-hosts episode audio.
Welcome Joe Bamberg, Lead Hardware Engineer at Sense
- Joe went to school at Miami, studying for pre-med.
- After a masters degree in EE, he ended up at Analog Devices (ADI) working on Energy metering ICs.
- Lyric labs
- Most meters are electromechanical, using moving parts to measure current via the Right Hand Rule. This then turns a wheel which measures "impulses per kwh"
- Past guest Larry Sears worked connected (gas!) meters.
- The first meters that weren't manually read used IR.
- Different generations of smart meters moved from measuring active power (Watt hour meter) to reactive power (VAR / apparent power / power factor / Line sag)
- Most homes have a power factor of 1 because of the primarily resistive loads.
- The onboard "filter based metering" used Hilbert filtering (transforms)
- Measuring current
- Joe worked on parts like:
- After ADI he ended up at Qualcomm / Pixtronics working on MEMS display technology. It used an IGZO (indium gallium zinc oxide) process
- The Sense is primarily in the US and Canada right now, measuring split phase, 120V power.
- Founder Mike Phillips has lots of experience with speech recognition (and disaggregation), which translated to the signal processing on Sense.
- Chris asked about if Sense shuts down, Joe later updated that this was addressed on the Sense blog.
- Internally there is a front end, isolated flyback, iMX7 and WiFi. It runs a custom distro of Linux.
- It's not just for monitoring power, it also monitors events. For instance, one of Joe's co-workers got a message "Your sump pump is kicking on"
- The solar version ships another set of CTs
- Edge processing (computing)
- There are a bunch of regulations NEC, UL, FCC, CE, CISPR
- Bolt helped with the initial mechanical design.
- It's small because of the variable size of installation cavities.
- Have more questions? Find Joe on Twitter as @thejoebamberg
Lead Hardware Engineer at Sense
sense.comAnalog Devices
analog.comLyric labs
eetimes.comusing moving parts to measure current via the Right Hand Rule
en.wikipedia.orgPast guest Larry Sears worked connected (gas!) meters.
theamphour.comactive power
en.wikipedia.orgHilbert filtering (transforms)
en.wikipedia.orgCT - current transformer
en.wikipedia.orgShunt
en.wikipedia.orgRogowski coil
en.wikipedia.orgADE7755
analog.comADE7858
analog.comQualcomm / Pixtronics
eetimes.comSense
sense.comFounder Mike Phillips
en.wikipedia.orgiMX7
nxp.comEdge processing (computing)
en.wikipedia.orgNEC
en.wikipedia.orgUL
ul.comFCC
fcc.govCE
en.wikipedia.orgCISPR
en.wikipedia.orgBolt
bolt.ioFind Joe on Twitter as @thejoebamberg
twitter.com